Advantages: 1.Flat-top hat Beam 2.7 joint articulate arm&10.4 touch display 3.Real-time energy monitor& Auto-Cali-bration System 4.Energy density is automatically adjustedwith spot size 5.Short pulse duration 5ns 6.Adjustable spot size 2-10mm 7.Stable power supply with High peak power 8.Water Filtration System 9.7*24 hour service/ Immediate help offered from the office located in The United States, Europe, and Australia. 10. 20 years of experience in Aesthetics equipment production and export. 11. Oem customized service, including software interface and body screen printing, color, etc. 12. Imported technologies and parts.
Share:
CE approved Q-Switched Laser Tattoo Removal hollywood facial and skin rejuvenataion Machine with local training and warranty in Europe

About our machine
1.Flat-top hat Beam
5.Short pulse duration 5ns
•
Q-switched Nd:yag laser makes the peak power increase, with the characteristics of high strength and low energy. When 1064nm laser passes through a KTP crystal, the frequency-doubled effect is obtained and the 532 nm laser is produced.
•
The wavelength of 1064nm can be well absorbed by melanin, which selectively makes small heat-absorbing particles (tattoo ink, melanin, etc.) suddenly heated and
damaged. Meanwhile, it does not damage the surrounding tissues and has a good
effect on the deep blue and melanin lesions, such as naevus fusconceruleus, nevus of Ota, bad tattoo, tattoo eyebrow. However, the curative effect on epidermal
pigmented diseases is poor.
• The wavelength of 532 nm can be strongly absorbed by red and brown
pigment, and it has good effect on superficial pigment diseases, such as
coffee spot, senile plaque, sunspot, freckle.
Balance uneven skin tones/Shrink pores

• In the use of the machine, doctors should flexibly adjust parameters according to the actual situation: individual differences (such as patient tolerance) treatment response, etc. Before using it, Skin tests should be performed to avoid accident.
•
For several treatments, the treatment should start with low energy, and increase it step by step. The doctor adjust the parameters in time according to the patient's response
•
Skin must be thoroughly cleaned before operation. On the one hand is to avoid residual cosmetics blasting during the treatment, on the other hand is that some areas require 3 to 7 days to stay free of water after treatment.
•
Alcohol or iodophor cotton ball, saline, sterile gauze, and disposable ice bag should be prepared before operation. The application of anesthetic usually takes 30 min-50 mins.
Removing the anesthetic and wiping skin with saline cotton ball before treatment.
•
The patient needs a lying position. Using saline gauze to cover eyes or wearing eye masks directly to avoid damage to eyes caused by laser misfire.
Turn on the machine. Firstly, select the wavelength according to the disease to be
treated. Then adjust the spot size on the handpiece, and set the parameters of energy,
frequency. Finally, start treatment.
•
The light is completely controlled by the foot switch, so the operator should be careful when pressing Ready. He should master the rhythm of the treatment so as
not to damage normal tissue by the laser.
•
Operators also should protect themselves, especially using Q532 nm green light, he must use protective goggles. In the treatment, the hands should be perpendicular to the healing skin area. Try to use low frequency (except for full face treatment). Try not to overlap treatment to prevent energy accumulation.

•
It is very important to do local cold compress after operation. Pay attention to the aseptic gauze in the place where the ice bag touches the operation area. Cold
compress for more than 30 minutes will reduce the occurrence of blisters after operation.
•
Using antibiotic ointment (generally erythromycin eye ointment) in the operative area to prevent infection. If scab forms, the patient must pay attention to avoid touching water and keeping it dry. The scab should be natural exfoliation, and not be forcibly removed.
It is very important to pay attention to sun protection after treatment. Good therapeutic effect is the combination of reasonable treatment parameters and
postoperative maintenance.
•
One week after the operation, the scab should naturally fall off. At this time the patient can use physical sun protection, such as using sun umbrella. Do not use
erosive products, such as keratolytics or efficacy products one month after treatment.
•
After the scab falls off, the patient should apply the sunscreen with SPF30+ when he goes out.

Laser Type | Q-Switched Nd:Yag | High Energy Q-Switched Nd:Yag | |||
Wavelength | 1064nm | 532nm | 1064nm | 532nm | |
Pulse Width | 5ns | 5ns | 8ns | 8ns | |
Pulse Energy | 500mJ | 200mJ | 1000mJ | 500mJ | |
Pulse Energy Range | 200-500mJ | 100-200mJ | 100-1000mJ | 100-500mJ | |
Frequency | 5Hz | 5Hz | |||
Spot Size | 2-10mm Adjustable | 2-10mm Adjustable | |||
Fluence | 0.2-16J/cm² | 0.1-6.3J/cm² | 1.3-32J/cm² | 0.6-16J/cm² | |
Aiming Beam | 635nm, <5mW | ||||
Electrical Requirements | 110-240VAC 50-60Hz 1200VA | ||||
Dimension | 351mm*925mm*775mm(without optical articulated arm) | ||||
Net Weight | 80 Kg | ||||
Item | EXQ-Laser | Others |
Power supply | TDK from Japan | China |
Pump delivery | 15m | 2.5m |
Power input | Wide range power input | Single power input |
Lamp | Medical grade Imported from Japan | China |
Switch | Medical grade imported from Japan | China |
Cord connectors | Medical grade imported from Switzerland | China |
PFC modular | Yes-power stabilizer, and 10% energy saving than normal ones | NO |