banner

Products

Picolaser Dark Spot Removing Machine
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41055020253.jpg
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41194352620.jpg
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41234218403.jpg
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41270517015.jpg
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41327600858.png
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41346220882.jpg
  • /uploads/202134052/small/picolaser-dark-spot-removing-machine41371238189.jpg

Picolaser Dark Spot Removing Machine

Treatment principle for pigmented dermatosis of Q-Switched Nd:YAG Laser Therapy system lies in selective photothermolysis with melanin as the chromophore.

Share:

Product Details

image005(001)


Q-Switched Nd:YAG Laser Therapy Systems

ExQ-Laser™ is safety and reliable with excellent performance, has successively achieved Certificates from CFDA , Medical CE and Australian TGA. Its unique designs also earn multiple global patents.

ExQ-Laser™ is newly released

Q-Switched Nd:YAG laser therapy system. The system has an optimal clinical treatment effect with following parameter designs: dual-wavelength switching of 1064nm & 532nm, pulse width short to 5ns and Energy output up to 1000mJ.


Introduction

ExQ-Laser™ integrated with real-time energy monitor, energy auto-changing by adjustable handpiece, water filtration system, sufficiently guarantee the safety and efficiency during using. New UI designs focuse on user experience, make the operation simpler and more convenient.


Correlation

Principle of Treatment

Treatment principle for pigmented dermatosis of Q-Switched Nd:YAG Laser Therapy system lies in selective photothermolysis with melanin as the chromophore.

Q-Switched Nd:YAG has higher Peak power and nanoseconds-level pulse width. Melanin in melanophore and cuticle formed cells have a short hot relaxation time. It could immediately make small selectively energy absorbed granules (tattoo pigment and melanin) blast without injuring surrounded normal tissues. The blasted pigment granules will be excreted from body through circulatory system.

image023_


Depth of penetration in the Skin

1.Melanin granules in skin

2.Melanin granules’ absorbing laser energy

3.Instantaneously blasted of melanin granules


Clinical Indications:

1064nm nevus of ota, black and blue tattoo

Epiderma

532nm freckles, café-au-lait spots, red tattoo

Derma

Advanced Tattoo Removal

Hypoderma

1064nm targets darkink 532nm targets red

Absorption Spectrum for Melanin and Hemoglobin


Prominent Advantages

Two stages Nd:YAG laser system with electro-optic Q-Switched technology, which output higher energy. The designs adopt cavity optimized schedule, make the pulse width as short as 5ns, get doubled output power density under the same energy.

Integrated laser energy monitor system inside, set warning signal when energy deviation over threshold, all to ensure treatment effectiveness and safety.

Optical splitter

Laser Laser output

Control Circuit

Energy monitor

Laser beam Electrical signal

Seven joints optical articulated arm with adjustable handpiece, spots size setting from 2 to 10mm. The energy synchronously changes following the setting spot size.

Flat-top beam output, uniformly distributed spot energy without any heat point, Achieve better treatment effect and less injuries.

Clinical Cases

image044_

Before After Before After

Nevus of ota treatment

Wavelength:1064nm Spot size:4mm Fluence:4.0J/cm² Frequency:3Hz

Tattoo removal

Wavelength:1064nm Spot size:4mm Fluence:4.0J/cm² Frequency:2Hz

image044_

Before After Before After

Freckles removal

Wavelength:532nm Spot size:2mm Fluence:1.5J/cm² Frequency:2Hz

Café-au-lait spots treatment

Wavelength:532nm Spot size:2mm Fluence:1.5J/cm² Frequency:2Hz


Statement

The technical parameters above are based on a large numbers of clinical practices. It is suggested that the surgeons adopt proper treatment parameters in according to real clinical situations.


Working Theory:

Treatment principle for pigmented dermatosis of Q-switched Nd:YAG laser Therapy system lies in selective photothermolysis with melanin as the chromophore.

Q-Switched Nd:YAG has higher Peak power andnanoseconds-level pulse width.Melanin in melanophore and cuticle formed cells have a short hot relaxation time.It could immediately make small selectively energy absorbed granules (tattoo pigment and melanin) blast without injuring surrounded normal tissues. The blasted pigment granules will be excreted from body through circulatory system.


Applications:

* 1064nm nevus of ota, black and blue tattoo.

* 532nm freckles, cafe-au-lait spots, red tattoo.


Advantages:

* Pulse width dowm to 5ns as Lutronic, Alma laser and Luminues.

* FDA, Medical CE,TGA and ISO13485 Certifications.

* Adjustable spot size 2-10mm.

* Vitrually flat top beam for minimal side effects.

* Real-time energy monitor & Auto-Calibration System.

* Two Stages ND:YAG system (double rods and double xenon lamp)


Technical Parameters

Laser type

Q-Switched Nd:YAG

High energy Q-Switched Nd:YAG

Wavelength

1064nm

532nm

1064nm

532nm

Pulse width

5ns

5ns

8ns

8ns

Pulse energy

500mJ

200mJ

1000mJ

500mJ

Pulse energy Range

200~500mJ

100~200mJ

100~1000mJ

100~500mJ

Frequency

5Hz

5Hz

Spot size

2~10mm adjustable

2~10mm adjustable

Fluence

0.2~16J/cm²

0.1~6.3J/cm²

1.3~32J/cm²

0.6~16J/cm²

Aiming beam

635nm,<5mW

Electrical requirements

110~240VAC 50-60Hz 1200VA

Dimension

351mmx925mmx775mm(without optical articulated arm)

Net weight

80Kg

Hot Tags: picolaser dark spot removing machine, suppliers, manufacturers, factory, discount, for sale

Send Inquiry

Related Products