Fractional Co2 laser equipment,The fractional co2 laser produces a beam of infrared light with the principal wavelength bands centering around 9.4 and 10.6 micrometers. With fractional laser resurfacing the laser beam is broken up or fractionated into many small micro beams which are separated so that when they strike the skin surface small areas of the skin between the beams are not hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.
Share:
Fractional Co2 Laser skin resurfacing Equipment for dermatological procedures including acne scar removal skin resurfacing and rejuvenation treatments

Fractional Co2 laser equipment
Implementation Standards
IEC 60601-1:2005/A1;2012
EN 60601-1:2006/A1:2013
ANSI/AAMI ES60601-1:2005+A2(R2012)
CAN/CSA-C22.2 No. 60601-1:14
IEC 60601-2-22: 2012
IEC/EN 60825-1: 2014
IEC/EN 60601-1-2 2007
Product Functions
1. Laser resurfacing surgery
2. Laser wrinkle removal surgery
3. Laser scar removal surgery
4. Laser blepharoplasty
5. Removal of pimented naevus, chloasmas, freckles, age pigments, warts, seborrheic keratosis, syringoma, acnes, milia, striae gravidarum;
6.Pore shrinkage; Skin tightening;
7. Laser hairtransplant; Laser breast augmentation;
CO2 dot matrix pixel laser adopts scanning dot matrix Way to emit a laser to form a burning area on the epidermis, which can be Directly penetrate the epidermis to reach the dermis layer, vaporize instantly Wrinkles and scar tissues stimulate collagen synthesis To initiate tissue repair, collagen remodeling and other skin reactions , Reach facial sculpture, fine lines disappear, skin becomes light Smooth and delicate, soothing acne marks.

Interface introduction

Scanning Therapy (1 treatment head)
Energy range: 1-170 mega joule (adjusted according to the guidance parameters, the deeper the skin tone, the lower the energy)
Scan figure: rectangle, triangle, circle. (Select according to the treatment site and habit)
Coverage rate: 20%, 30%, 40%, 50%, 60%, 70%, 80% (according to the guidance parameters, it is suggested that 40-60 is easy to increase the possibility of adverse reactions)
Image size: (small area precision treatment, rapid treatment of large area)
Working mode:
CW: large degree of heat dispersion, large area treatment (fine lines, removing yellow and whitening, tightening pores)
SP: deep penetration, local treatment (acne, skin rejuvenation, scar)
System output mode:
Repetition mode: a skilled operator.time-saving.
Single mode: It is a suggested way, preferred choice for beginner
Continuous mode: local continuous treatment, large area treatment (scar, freckle removal...)
Surgical Therapy ( two treatment heads)
Power
CW pattern: 0-30W
SP pattern: 0-15W
Pulser pattern: 0-30W
Time of light exaction
0.01-1s (laser energy stays at the skin surface for time)
Work pattern
CW mode: shallow penetration, large diffusion, suitable for large-area treatment, beginner choice.
SP mode: deep penetration, small diffusion, suitable for part of treatment, skilled operator choice
Pulser Mode: the penetration depth, the energy diffusion degree is located in the middle of the two.
Output mode:
Repetition mode: a skilled operator.time-saving.
Single mode: suggested way, preferred choice for beginner
Continuous mode: large area treatment (neoplasm removal, tissue cutting...)

Gynecological private hand sets (4 treatment heads in total:2 inside and 2 outside)
● Circular Cone (inside treatment of vagina)
This treatment head is mainly used for the treatment of vaginal laxity (VRS: Vaginal Relaxation Syndrome).
The light extraction is circular "full emission", the operator can step back according to the scale.
● Bevel (inside treatment of vagina)
This treatment head is mainly used for the treatment of stress urinary incontinence.
The light extraction is a mirror "half emission", the bevel of treatment head is vertical upward, the operator can retreat according to the scale.
● one point (outside treatment of vagina)
This treatment head is mainly used for vestibular and vaginal labia, to improve atrophy and vulva color
● Two points (outside treatment of vagina)
This hand is mainly used for labia large Yin, to improve atrophy and vulva color

Operation interface description
Energy range: 1-120 mega-joule
Scan figure: rectangle, triangle, circle.(Select according to the treatment site and habit)
Coverage rate: 20%, 30%, 40%, 50%, 60%, 70%, 80% (according to the guidance parameters, it is suggested that 40-60 is easy to increase the possibility of adverse reactions)
Image size: (small area precision treatment, large area rapid treatment)
System output mode:
Repetition mode: aging and other serious problems, skilled operator choice, time-saving.
Single mode: suggested way, beginner choice
Continuous mode: higher-order treatment mode, more dangerous, use with caution!!

Application of Scope
The CO2Laser (10600nm) is indicated for use in surgical applications requiring
the ablation, vaporization, excision, incision, and coagulation of soft tissue in
dermatology and plastic surgery, general surgery.
Dermatology, Plastic Surgery and General Surgery procedures
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos,telangiectasia,
squamous and basal cell carcinoma, warts and uneven pigmentation.
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications.
Blepharoplasty
Site preparation for hair transplants
The fractional scanner isfor treatment of wrinkles and skin resurfacing.

Before and after the operation
Preoperative
① Customer Preparation:
- Make sure to tell your patient indications, contraindications, adverse reactions Postoperative maintenance precautions and operation limitations and sign the notice.
- Please ask customers to wear comfortable, convenient to expose the treatment area clothing, or use customer special clothing.
- Make sure to clean and disinfect (shave) treatment area (private area and equipment with alcohol-free aniodine)
② Operator preparation
- Mark the treatment site with the area where the client wants to treat.
- Take the photo of treatment area, after the skin detector and record the before and after (please make sure the data as correct as possible).
- Ask the client to adopt the appropriate body position according to the treatment area.
- preoperative anesthetic cream for 30min, ice compress, relieve and calm advance pain
- Private treatment may be considered use lubricant as appropriate, but must be sterile
- Preoperative sensitive measurement
In treatment Process
Matters need attention:
The light spots avoid duplication.
Sensitive test (starting from under the ear)
If you can not decide the how much of energy suitable, just use small energy, make sure all surgry under the safe.
Halve your eyes
Maintain intraoperative communication and observation, wipe sweat, tears, etc
Treatment endpoint:
Shallow whitening,tender skin,control oil: slightly red,slightly white;
Deep remove scar acne pit: obvious white-scab
* * Within the range of tolerable and guiding energy, the higher the energy, the greater, the risk of adverse effects, based on treatment experience.

Post-operative precautions
Scan & Surgical Therapy
At once:
The treatment site is reddish and burning, which is normal; apply the mask immediately until the temperature of skin drops to normal
Within three days:
Do not touch raw water for 3 days (available normal saline);
Do not makeup and avoid conventional skin care products, makeup after 1 week or waiting the scab off;
Do not participate in intense sports, do not steam the sauna to avoid heavy sweating;
Seven days of scab
Let the scab skin fall off by itself, do not use the hand to scratch;
For one week, LED red light irradiation was treated once daily to promote healing
Within six weeks
Make sure apply efficacy skin care products after at least two weeks
Strict of sun protection (SPF30 or above), and with a sunshade.
Strengthen hydration and moisturizing (facial mask)
Avoid spicy food, stimulation, tobacco and alcohol, photosensitive food; supplement protein, appropriate supplement Vc and Ve food.(Lemon, papaya)
Gynecoiatry
Immediately cold compress + fill water until the temperature drops to normal, apply antibacterial gel locally
Red swelling, secretions will increase, is a normal phenomenon, can prepare pads
No strenuous exercise for first day.
Do not ride a bicycle, take a bath, or have sex within a week
⑤ One month later before receiving treatment with the other devices
⑥ After 48 hours, half a month, a month after treatment, the operator can ask the patient to re-visit.
Treatment course advices
Skin reconstruction
Once in every 2-3 months, for a course of 2-3 times;
* * It should be noted that too intensive treatment will not achieve a better treatment effect, but on the contrary, the probability of adverse reactions will be greatly increased.Therefore, the minimum treatment interval should not be less than 2 months. Make sure give the skin have enough time to repair and rebuild itself.
Private health
Once in every month, one course of 1-2 times;
Postpartum repair
Once in every month, a course of 2-3 times;
Gynecologic disease (stress urinary incontinence (SUI), mild uterine prolapse):
once in every month, a course of 2-4 times;

|
Laser Type |
RF-excited CO2 laser |
|
Wavelength |
10.6μm |
|
Laser Average Power |
CW:0-30W SP:0-14W CW:0-15W SP:0-7W |
|
Laser Peak Power |
CW:30W SP:60W CW:15W SP:30W |
|
Handpieces |
Surgical Handpieces(f50mm,f100mm) |
|
Scan Handpieces(f50mm,f100mm) |
|
|
Gynecology Handpieces(f127mm) |
|
|
Spot Size |
0.1mm |
|
Scan Size |
Up to 20mm*20mm |
|
LCD screen |
12.1 inch |
|
Aiming beam |
635nm,<5mW |
|
Electrical |
100-240 VAC,50-60Hz,800VA |
|
Dimensions(L*W*H) |
460mm*430mm*1170mm(not including articulated arm) |
|
Net weight |
40kg |