banner

Products

CE and Fda Approved Diode Laser hair removal and skin rejuvenation device with big power
  • /uploads/202134052/small/-fda-approved-diode-laser02098395797.png
  • /uploads/202134052/small/-fda-approved-diode-laser02120325927.png
  • /uploads/202134052/small/-fda-approved-diode-laser02119605892.png
  • /uploads/202134052/small/-fda-approved-diode-laser02153810778.png
  • /uploads/202134052/small/-fda-approved-diode-laser02136155947.png
  • /uploads/202134052/small/-fda-approved-diode-laser02140505912.png
  • /uploads/202134052/small/-fda-approved-diode-laser02152761034.png

CE and Fda Approved Diode Laser hair removal and skin rejuvenation device with big power

Applications: Remove unwanted hair completely and permanently. Applicable to any hair color and all skin types. Advantages: 1.The gold standard in permanent hair removal effectively for all skin type including tanned skin-clinically documented and proven results. 2.Advanced Unichill technology handpiece provides continuous contact cooling of the epidermis. 3.Ergonomically design finger trigger for easy, comfortable operation. 4.Straight forward and user friendly interface. TGA,,ISO13485 and Medical CE approval for full cover for both end users and distributors worldwide.

Share:

Product Details

CE and Fda Approved Diode Laser hair removal and skin rejuvenation device with big power

banner 2

A. Introduction principle

Semiconductor laser hair removal uses the principle of selective photothermal action, the energy of the laser is absorbed preferentially by the melanin in the hair, and light energy is into heat energy, the heat generated instant local high temperature, destroys hair follicles and hair dry, hinder and terminate hair growth, play a permanent hair removal effect. Because the photothermal action is confined to the hair follicle, it prevents the thermal energy from causing damage to the surrounding tissue.

WORKING

A. Introduce the interface and the handle

1. After selecting the skin type and site, the parameters displayed on the interface are the recommended parameters, and then do the skin test with the interface parameters.

2. The temperature of the handle treatment head can be adjusted, the adjustment range is -4℃ to 10℃, the default is 4℃, and the temperature is generally adjusted. When the hair is particularly thick, the light absorbed is more and the photothermal reaction is relatively strong, the temperature can be appropriately lowered.

3. The Total energy in the beauty interface is the total energy, and the total energy is the total energy needed to treat a certain part. Total energy value is determined by skin type and treatment site, and cannot be manually adjusted; Frequency The light output frequency is determined by skin type and treatment site, and cannot be manually adjusted;

4. The Progress in the beauty interface refers to the treatment progress display. When the user selects the skin type and treatment site, the system will automatically give the recommended energy density, total energy and light frequency, and automatically calculate the total time of the treatment; when the user starts treatment, the progress bar will make progress and display the remaining time in real time; when the progress bar reaches 100%, when the treatment is completed, the system will automatically switch to the Standby state and stop the laser output.

 


laser hair removal

diode laser

1064nm

755nm


A. Introduce the operation process

1. Item preparation: leather knife, water, tongue pressing plate, cold gel, small bowl, ice bag, goggles, alcohol cotton pads, face towel

2. Informed consent form was signed to exclude contraindications

3. Take preoperative photos (preferably both before and after shaving)

4. The hair was scraped off of the treatment area

5. Cleaning (skin and probe)

6. Select the appropriate parameters according to the skin color and hair color and the treatment site

7. Apply gel (about 2-3mm thick)

8. Bring your goggles

9. Do the skin test, the details are as follows:

(1) A representative site was selected for the experimental treatment. If hair removal is performed on the entire face, you should choose locations that do not affect the appearance of the face, such as the root of the ear, and note that the selected skin does not have symptoms such as damage or infection.

 

(2) The treatment head was vertically attached to the skin and properly pressurized, sliding with the hair growth direction for 2-3 times. Wait for 5-10 minutes, wipe off the gel to observe the test effect. If the skin appears erythema or edema, and the surrounding skin no reaction is the best effect. The following treatment can be set at the same energy level. If no visible changes on the skin, add 1-2J / cm 2. If the patient feels severe pain or blisters in the skin test area, it may be repeated due to high energy or excessive energy reduction.

10. After the skin test, it can be formally operated. The large area can be treated by cross method. One site generally slides 4 to 6 times and can be horizontal three times and vertical three times. The number of slides is not fixed but is mainly based on the endpoint reaction of the skin. It can use the stamp operation technique when the site is small. But to reduce the frequency, such as 2-3 HZ. During the operation, always ask the customer and observe the skin reaction.

11. After the operation, scrape off the gel and clean the skin and probe.

12. Ice compress (armpit, lip hair, bikini area hair follicle is more developed, the light and heat reaction is strong, so it is recommended to apply ice for 10-15 minutes. Legs, hands and other parts of fine hair, such as the customer did not feel hot or erythema after surgery, not ice compress, or ice compress for about 5 minutes)

13. Explain the postoperative precautions

 

B. course of treatment

4-6 times is a course of treatment, once a month.


hair removal machine


Diode Laser FAQs

 

What is Diode Laser?

A Diode laser is a semiconductor device that produces coherent radiation (in which the waves are all at the

Same frequency and phase) with a wavelength of 808nm it has a deep penetration and is attracted to the

pigment in the hair and skin. It can be used on skin types 1-6 for hair reduction.

 

How does it work?

Lasers remove hair though a process called Selective Photo Thermolysis in which energy in the form of

wavelengths is delivered into the hair shaft and follicle. The light is attracted to and absorbed by the melanin

and this heats the tissue causing thermal damage to the follicle resulting in hairs weakening or not growing

back.

 

How many treatments?

The amount of treatments can vary from person to person but usually 4-6 treatments will give you a reduction

of up to 80-90% and then maintenance treatments 2~3 times a year. If there is a hormonal imbalance you may

be required for more maintenance treatments.

 

How much time between each treatment?

Depending on the area being treated it can be anywhere from 4-6 weeks in between treatments. The hair

growth cycle on the face is usually four weeks while the legs is normally six weeks but this can vary from

       person to person.

 

Can all hair be treated?

Diode laser targets the pigment in the hair so the hair must be medium brown to black the darker the better,

       for best results.

Behind the Diode laser technology you can also treat blonde, red grey or white hair. Due to the less amount

       of pigment within blonde, red grey or white hair, the results will be less impressive as the black hair.

 

Is laser safe?

Laser has been around for a long time now and the technology is making treatments safer than ever.

The AuruMed Diode device is preprogrammed for specific skin types and different parts of the body as

long as the client is a good candidate and has no contra-indications and is following both pre and post care

the risk of any side effects is minimal.

Dermatologists recommended post laser skin care products, Tiferono.

 

HIFU after treatment care products Tiferono by fotromed(1)

Technical Parameter
Brand
Razorlase®
Laser output power
800W Max
Wavelength
755/808/1064 nm/3 in 1
Function
Permanent Hair Removal
Laser class
Class 4
Electric Security Classification
Type B ClassⅠ
Pulse width
5ms-240ms
Frequency
1Hz-10Hz
Spot size
12mm×16mm
Fluence
1-60J/cm2
Screen
12.1 Inch Touch Color Screen
Cooling methods
Air cooling, water cooling
and semi-conductor cooling
Dimension(L*W*H)
400*370*1090mm
Weight(NW)
50 kg


Hot Tags: CE and Fda Approved Diode Laser hair removal and skin rejuvenation device with big power, suppliers, manufacturers, factory, discount, for sale

Send Inquiry

Related Products