Features: 1. Our diode laser with FDA and medical CE approved. 2. 10 laser bars imported by Jenoptik Diode Lab Gmbh/Germany. 3. Skin Cooling: One-piece Patent Unichill Cooling System. 4. Treatment Specification: 6 skin types, 5 treatment areas 30 clinical data for reference and options. 5. System Protection: 10 safety items checking system. As an integrated situation, Razorlase+ combines the benefits of all 3 wavelengths 808nm 755nm 1064nm, 3 wavelengths have different characteristics. Targeting different tissue depths as well as structures within the hair follicle. Thus to the greatest extent to ensure effective treatment and is virtually painless. Razorlase+ achieves the safest and most comprehensive hair removal treatment available today. Really reach: painless, fast, and effective.
Share:
CE and FDA approved 1064 755 808nm Diode Laser Permanent Hair Removal Machine for salon and clinics
Razorlase adopts 808nm golden standard for laser hair removal. The system uses the most advanced intelligent control with accurate laser output energy and stable wavelength, which guarantee the perfect treatment effects.
Razorlase diode laser therapy system holds a wavelength of 808nm, which can deeply reach hair follicle. According to selective photothermolysis principle,rich melanin in hair follicle will completely absorb laser energy and produce heat. Meanwhile,hair follicle stem cells will be damaged and hair growth will be inhibited.

The 808nm close to infrared laser is best for retaining melanin so it is profoundly successful in various pieces of skin, hair follicles and reach to eliminating any hair effectively, with enduring outcomes.
The innovation behind the Diode 808 laser guarantees the skin assimilates less laser, lessening the danger of hyper-pigmentation.
Sapphire touch cooling framework can ensure that treatment more protected and effortless.
Utilizing specific light retention, the Diode 808 laser is specially consumed by the melanin of the hair. The light vitality is taken up by the hair follicle and changed over to warm vitality, and insignificant vitality is moved to the skin. This specially warms the hair and its DNA, while lessening oxygen association around hair follicle – decreasing the opportunity of hair regrowth. Uncommon cooling innovation is applied all the while during treatment to cool the skin and ensure skin.
The Diode 808 laser forever decreases hair on all skin types, including light complexion and olive or African-American skin. Medicines are best on medium to dull hair on any skin type. Fine and light hair is extremely hard to treat. Blonde, red, white and silver hair can't be dealt with.
It would be ideal if you read our correlation among IPL and laser for hair evacuation and why we don't advocate the utilization of IPL here:LASER versus IPL.

Most patients feel a warm sting as the laser enters the hair follicle. Numerous individuals portray the sensation as the snap of an elastic band against their skin. To limit the uneasiness, a skin sedation and cool gel is applied to the skin before treatment.

A. Introduce the interface and the handle
1. After selecting the skin type and site, the parameters displayed on the interface are the recommended parameters, and then do the skin test with the interface parameters.
2. The temperature of the handle treatment head can be adjusted, the adjustment range is -4℃ to 10℃, the default is 4℃, and the temperature is generally adjusted. When the hair is particularly thick, the light absorbed is more and the photothermal reaction is relatively strong, the temperature can be appropriately lowered.
3. The Total energy in the beauty interface is the total energy, and the total energy is the total energy needed to treat a certain part. Total energy value is determined by skin type and treatment site, and cannot be manually adjusted; Frequency The light output frequency is determined by skin type and treatment site, and cannot be manually adjusted;
4. The Progress in the beauty interface refers to the treatment progress display. When the user selects the skin type and treatment site, the system will automatically give the recommended energy density, total energy and light frequency, and automatically calculate the total time of the treatment; when the user starts treatment, the progress bar will make progress and display the remaining time in real time; when the progress bar reaches 100%, when the treatment is completed, the system will automatically switch to the Standby state and stop the laser output.

A. Introduce the operation process
1. Item preparation: leather knife, water, tongue pressing plate, cold gel, small bowl, ice bag, goggles, alcohol cotton pads, face towel
2. Informed consent form was signed to exclude contraindications
3. Take preoperative photos (preferably both before and after shaving)
4. The hair was scraped off of the treatment area
5. Cleaning (skin and probe)
6. Select the appropriate parameters according to the skin color and hair color and the treatment site
7. Apply gel (about 2-3mm thick)
8. Bring your goggles
9. Do the skin test, the details are as follows:
(1) A representative site was selected for the experimental treatment. If hair removal is performed on the entire face, you should choose locations that do not affect the appearance of the face, such as the root of the ear, and note that the selected skin does not have symptoms such as damage or infection.
(2) The treatment head was vertically attached to the skin and properly pressurized, sliding with the hair growth direction for 2-3 times. Wait for 5-10 minutes, wipe off the gel to observe the test effect. If the skin appears erythema or edema, and the surrounding skin no reaction is the best effect. The following treatment can be set at the same energy level. If no visible changes on the skin, add 1-2J / cm 2. If the patient feels severe pain or blisters in the skin test area, it may be repeated due to high energy or excessive energy reduction.
10. After the skin test, it can be formally operated. The large area can be treated by cross method. One site generally slides 4 to 6 times and can be horizontal three times and vertical three times. The number of slides is not fixed but is mainly based on the endpoint reaction of the skin. It can use the stamp operation technique when the site is small. But to reduce the frequency, such as 2-3 HZ. During the operation, always ask the customer and observe the skin reaction.
11. After the operation, scrape off the gel and clean the skin and probe.
12. Ice compress (armpit, lip hair, bikini area hair follicle is more developed, the light and heat reaction is strong, so it is recommended to apply ice for 10-15 minutes. Legs, hands and other parts of fine hair, such as the customer did not feel hot or erythema after surgery, not ice compress, or ice compress for about 5 minutes)
13. Explain the postoperative precautions

Diode Laser FAQs
What is Diode Laser?
A Diode laser is a semiconductor device that produces coherent radiation (in which the waves are all at the
Same frequency and phase) with a wavelength of 808nm it has a deep penetration and is attracted to the
pigment in the hair and skin. It can be used on skin types 1-6 for hair reduction.
How does it work?
Lasers remove hair though a process called Selective Photo Thermolysis in which energy in the form of
wavelengths is delivered into the hair shaft and follicle. The light is attracted to and absorbed by the melanin
and this heats the tissue causing thermal damage to the follicle resulting in hairs weakening or not growing
back.
How many treatments?
The amount of treatments can vary from person to person but usually 4-6 treatments will give you a reduction
of up to 80-90% and then maintenance treatments 2~3 times a year. If there is a hormonal imbalance you may
be required for more maintenance treatments.
How much time between each treatment?
Depending on the area being treated it can be anywhere from 4-6 weeks in between treatments. The hair
growth cycle on the face is usually four weeks while the legs is normally six weeks but this can vary from
person to person.
Can all hair be treated?
Diode laser targets the pigment in the hair so the hair must be medium brown to black the darker the better,
for best results.
Behind the Diode laser technology you can also treat blonde, red grey or white hair. Due to the less amount
of pigment within blonde, red grey or white hair, the results will be less impressive as the black hair.
Is laser safe?
Laser has been around for a long time now and the technology is making treatments safer than ever.
The AuruMed Diode device is preprogrammed for specific skin types and different parts of the body as
long as the client is a good candidate and has no contra-indications and is following both pre and post care
the risk of any side effects is minimal.
Dermatologists recommended post laser skin care products, Tiferono.